Fire Alarm Systems > Silent Knight Fire Alarms > SLC Devices
SLC Devices

Silent Knight SLC Devices


SD505-TCHB100 Handheld Detector Programmer

SD505-TCHB100 Handheld Detector Programmer

SD505-TCHB100 Handheld Detector Programmer

The SD505-TCHB100 was designed to program addresses of detectors used with Silent Knight IntelliKnight systems. Although this programmer is not required to program the detectors, many installers find it easy and more convenient than the standard empty base to the control panel programming method.




SD500-AIM Addressable Input Module

SD500-AIM Addressable Input Module

SD500-AIM Addressable Input Module

The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight's IntelliKnight fire control panel. The SD500-AIM and SD500-MIM are designed to be used with pull station, water flow switches, and other applications requiring dry contact alarm initiation devices.




SD500-ARM Addressable Relay Module

SD500-ARM Addressable Relay Module

SD500-ARM Addressable Relay Module

The SD500-ARM is an addressable device that adds great flexibility to the IntelliKnight system. Providing two Form C contacts rated at 2.0 amps @ 30 VDC. The SD500-ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit.

Downloads:



SD500-MIM Miniature Addressable Input Module

SD500-MIM Miniature Addressable Input Module

SD500-AIM Addressable Input Module

The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight's IntelliKnight fire control panel. The SD500-AIM and SD500-MIM are designed to be used with pull station, water flow switches, and other applications requiring dry contact alarm initiation devices.




SD500-PS Addressable Pull-Station: Single Action

SD500-PS Addressable Pull-Station: Single Action

SD500-PS Addressable Pull-Station: Single Action

IntelliKnight's addressable pull stations combine fast response with pin-point location ID.




SD500-PSDA Addressable Pull-Station: Dual Action

SD500-PSDA Addressable Pull-Station: Dual Action

SD500-PSDA Addressable Pull-Station: Dual Action

IntelliKnight's addressable pull stations combine fast response with pin-point location ID.




SD505-AHS Addressable Heat Detector

SD505-AHS Addressable Heat Detector

SD505-AHS Addressable Heat Detector

The SD505-AHS is a heat detector suited to virtually any commercial setting. The SD505-AHS is an absolute temperature device. This means that it responds to an alarm immediately if the temperature goes above the trip point (programmed at the panel).




SD505-APS Addressable Photoelectric Smoke Detector

SD505-APS Addressable Photoelectric Smoke Detector

SD505-APS Addressable Photoelectric Smoke Detector

The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible smoke particles.




SD505-AIS Addressable Ionization Type Smoke Detector

SD505-AIS Addressable Ionization Type Smoke Detector

SD505-AIS Addressable Ionization Type Smoke Detector

The SD505-AIS has responsive, yet high operational stability for an extremely wide range of uses. The SD505-AIS can be used in areas where early warning of trouble from super-heated or flaming combustibles is expected.

The detector features automatic compensation for contamination and a simple detector sensitivity test procedure that can be run from the panel or remotely (using the IntelliKnight 5590 or 5595 software with a Windows TM based computer).

(Used with the 5820XL and 5808 Only)




SD505-6AB 6-Inch Standard Base

SD505-6AB 6-Inch Standard Base

SD505-6AB 6-Inch Standard Base

Use with conventional or addressable smoke detector heads.




SD505-6SB 6-Inch Addressable Sounder Base

SD505-6SB 6-Inch Addressable Sounder Base

SD505-6SB 6-Inch Addressable Sounder Base

The SD505-6SB provides flexible notification capabilities where you need it. The SD505-6SB adds an audible output function to the IntelliKnight Photo, Ion, or Heat addressable detectors. The SD505-6SB can be used as a single station, multi-station or as a system sounder.

Notes: Used with the 5820XL Only
Requires IntelliKnight Version 6.0




SD505-6RB 6-Inch Accessory Relay Base

SD505-6RB 6-Inch Accessory Relay Base

SD505-6RB 6-Inch Accessory Relay Base

Add a relay output to an addressable detector with Silent Knight SD505-6RB.

The SD505-6RB adds a relay output function to an addressable detector. Providing two Form C contacts rated at 8.0 amps for 240 VAC, 120 VAC and 30 VDC. The SD500-6RB allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit.

(Used with the 5820XL Only)




SD505-6IB 6-Inch Isolator Base

SD505-6IB 6-Inch Isolator Base

SD505-6IB 6-Inch Isolator Base

Isolates short circuit wiring on an SLC loop without shutting down the entire loop.

Note: Requires IntelliKnight Version 6.0




SD505-ADHR Addressable Duct Housing and Relay

SD505-ADHR Addressable Duct Housing and Relay

SD505-ADHR Addressable Duct Housing and Relay

Detect smoke in air handling systems and prevent re-circulation with Silent Knight's addressable duct smoke detector.




SD505-ADH Addressable Duct Housing

SD505-ADH Addressable Duct Housing

SD505-ADH Addressable Duct Housing

The SD505-ADH analog addressable duct smoke detector detects smoke and products of combustion present in air moving through an HVAC duct to prevent re-circulation of smoke into the air handling system. The SD505-ADH is a heavy duty metal housing with a pre-installed detector base. When smoke is detected in a duct, the unit communicates the condition to the IntelliKnight control panel. The panel, in turn, depending on programming, turns off fans, blowers, and other devices.




SD505-DTS Remote Test Switch

SD505-DTS Remote Test Switch

SD505-DTS Remote Test Switch

The SD505-DTS is a remote test switch that is used with the SD505-ADHR so you can remote test the Duct Detector. It also provides LED indication of the status of the SD505-ADHR.




SD500-LIM Line Isolator Module

SD500-LIM Line Isolator Module

SD500-LIM Line Isolator Module

Isolate SLC loop problems without losing the entire loop.

Isolate a short circuit wiring fault on a SLC loop using a SD500-LIM. Normally if the control panel detects a short on the SLC loop the entire loop is disabled. When isolator modules are used and a short occurs on the SLC loop, it will be detected as a trouble but all the SLC devices that are protected by a line isolator module will continue to operate.




SD500-ANM Addressable Notification Module

SD500-ANM Addressable Notification Module

SD500-ANM Addressable Notification Module

The SD500-ANM gives you the flexibility to add notification circuits wherever you need them. The SD500-ANM is a supervised addressable notification device that provides you with additional notification circuits on the IntelliKnight's SLC loop. Controlled by the SLC loop up to 127 SD500-ANM modules can be used on an SLC loop. The SD500-ANM provides a reverse polarity Class A or Class B notification appliance circuit with an aux power input. Each SD500-ANM is provided power from a separate power supply and is controlled by the main panel. Power can be provided near the signaling appliance to reduce the wire gauge requirements or power can come from a main power supply and be controlled separately by the individual notification modules. All of the panels 20 notification patterns can be produced by the SD500-ANM.

(Used with the 5820XL Only)




SD500-SDM Smoke Detector Module

SD500-SDM Smoke Detector Module

SD500-SDM Smoke Detector Module

The SD500-SDM allows you to assign an address to a loop of conventional detection devices. These devices can be dry contacts such as pull stations and heat detectors, or 2-wire smoke detectors. This means you can retrofit an existing building and utilize existing conventional devices. The SD500-SDM uses a 24VDC auxiliary power input to power the conventional loop, and is connected to the SLC loop via two wires. The conventional loop can be configured as Class A or Class B giving you the flexibility to handle any job.

(Used with the 5820XL Only)
Requires IntelliKnight Version 6.0