| Power Source |
IE-8MD 12 ~ 18V DC, 500mA
MY-CU, MYH-CU or MYW-P3CB 18V DC. *Use PS-1820UL Power Supply.
|
| Communication |
4 or 2-tone chime, with volume control. Call-in timer: 45 seconds. Pick up any handset to reply. Monitor timer: 2-1/2 minutes.
|
| MYW-P3CB Auto-Scan Duration |
5 or 10 seconds, each camera. Press MONITOR button for 1-1/2 seconds to trigger auto-scan. |
| Wiring |
2 conductor, 18AWG, non-shielded. (Use Aiphone #841802.)
6 wires, looped to Monitors. (Use Aiphone #841806.)
4 wires to IE-8 handsets. (Use Aiphone #822206.) |
| Distance |
Video Door to MY-CU/Adaptor: 165' with 22AWG, 330' with 18AWG.
MY-CU/Adaptor to last MYH-CU: 115' with 22AWG, 245' with 18AWG. |