Intercom Systems > Aiphone Intercom Systems > GF Multi-Unit Audio/Video Entry System

Aiphone GF: Audio/Video Multi-Unit Entry System

AIPHONE's GF video system is the simplest video apartment entry intercom system available in the market, allowing easy installation and programming. This concierge station is used in place of a door bell to give you video and communication with all tenants and entrance stations before letting someone in, as well as reply to panic call situations. When a tenant pushes an emergency switch the panic call turns on with the alarm in both the apartment and at the concierge station. All that is needed for a complete installation is 2 pairs of wires throughout the whole building. The full modular entrance station is made of specially designed, vandal resistant zinc diecast panels, and is weather-resistant while weathering hoods and surface mount boxes are available upon request. The system's apartment stations (GF-1MD audio/video & GF-1D audio only) are compact and slim, designed for surface mount installation and are equipped with door release button and 2 additional service buttons. The GF is flexible, allowing users to mix and match modules to create the exact system configuration and features for their own needs. And with the GF video expansion module, you can connect up to 250 audio/video monitors to the system (the current system is limited to 150 stations). Due to the advanced features and easy installation, the GF system is the ideal communication solution for new and existing multi-apartment applications.

Use QuikSpec to specify the GF system

Features
  • One to five entrance panels and 250 tenant locations (Note wire distance specifications on larger systems)
  • Both audio/video and audio-only entrance panels can be combined in the same system
  • Flush mount modular design allows the entrance panel to have digital keypad calling and LCD display, or individual call buttons for each tenant
  • Digital entrance panel kits available for easy designing, selling, and installation
  • Up to two inside audio/video or audio-only stations for easy communication with visitor
  • Security Guard or Concierge Station can be included to provide communication from office/lobby to tenants.
  • Panic call switch can be added to tenant locations for emergency calling to guard/concierge
  • Simple wiring with only two sets of 2 conductor cable run in common throughout the system (One pair for audio and one pair for video)
  • Access control from inside station to calling entrance station (door release)
  • Optional individual doorbell at each tenant's door to ring inside station (different tone)
  • Door release timer (5~20 seconds), allowing easy entry of postal or delivery workers
Specifications
    Power Source24V DC, 0.7A Max. (30mA in standby) Use PS-2410LC only.
    Power SupplyPS-2410LC for each type of adaptor. (One each for GF-BC, GF-VBC/A, GFW-VBC. On additional GF-VBC/A if two monitors are included per tenant.)
    Current ConsumptionGF-BC: 0.7A, 30mA in standby
    GF-VBC/A: 0.95A, 20mA in standby
    GF-NS: 80mA (continuous)
    Station CapacityMaximum 250 total tenant addresses with 10- key digital calling. Max 100 stations when using individual tenant call buttons.
    Entrance StationsMax. 5 (audio/video or audio-only)
    Apartment StationMax. 2 stations per apartment, intermixable (or less for larger systems. Max.150 GF-1MD's per system)
    Max. stations per trunk line50 GF-1D's
    25 GF-1MD's (Either loop wired or using GF-4Z's)
    Trunk Lines6 Video trunks from GF-VBC/A
    Any number of audio trunks from junction point
    Talk Path Single channel with privacy
    Calling TonesElectronic ring tone from entrance station(s)
    Differentiated ring tone from individual doorbell Door Release Contact 4A at 24V AC/DC (EL, EL terminals on GF-DA/A or GF-DA/B, dry closure)
    Wiring2-wire common bus wiring from Entrances to GF-BC
    2-wire common bus wiring from Entrances to GF-VBC/A
    2-wire common bus wiring from GF-VBC/A to GF-1MD's
    2-wire common bus wiring from GF-BC to GF-1MD's or GF-1D's
    WireUse Aiphone wire #872002 for Audio Pair. 2 conductors, solid copper, shielded, polyethylene insulation, 20 AWG.
    Use Aiphone wire #871802 for Audio Pair. 2 conductors, solid copper, PE insulation, FPLR, 18 AWG.
    NOTE: Proper operation or warranty for the system is not guaranteed with wire other than specified.
    DistanceGF-BC to Junction Point: 16' with 20AWG
    GF-VBC/A to Entrance Stn: 330' with 18AWG
    GF-BC & GF-VBC/A to PS-2410LC: 16' with 20AWG
    GF-VBC/A to farthest GF-1MD: 500' with 18AWG (w/1 monitor); 330' with 18AWG (w/2 monitors)
    GF-BC to farthest Audio Only Entrance(s): 980' with 20AWG
    GF-BC to farthest Handset station: 980' with 20AWG
    Total cumulative audio wire distance must not exceed 7,920' per system with 20AWG
    Note: GF System is special order. Restock fees apply


Entry Panel Equipment
GF-1MDK Audio/Video Tenant Station

GF-1MDK Audio/Video Tenant Station

Aiphone Intercom GF-1MDK Audio/Video Tenant Station

The GF-1MD is used to view and communicate with a person at a GF entrance panel. The unit features a 4" B&W CRT monitor, release button and a call tone volume control. Up to 250 stations can used in system.




GF-102HB Aiphone Hooded surface-mount box for GF: Multi-Unit Entry System

GF-102HB Aiphone Hooded surface-mount box for GF: Multi-Unit Entry System

GF-102HB Aiphone Hooded Surface-Mount Box

Hooded surface-mount box for the GF: Multi-Unit Entry System.




GF-103HB Aiphone Hooded surface-mount box for the GF: Multi-Unit Entry System

GF-103HB Aiphone Hooded surface-mount box for the GF: Multi-Unit Entry System

GF-103HB Hooded surface-mount box for the GF: Multi-Unit Entry System

Dimensions: 13-5/16" x 6-1/8"




GF-202HB Aiphone Hooded surface-mount box for GF: Multi-Unit Entry System

GF-202HB Aiphone Hooded surface-mount box for GF: Multi-Unit Entry System

GF-102HB Aiphone Hooded Surface-Mount Box

Hooded surface-mount box for the GF: Multi-Unit Entry System
Dimensions: 9-9/16 x 11-7/16"




GF-2B Aiphone Back Box for GF Common 2-Wire Multi-Unit Entry System

GF-2B Aiphone Back Box for GF Common 2-Wire Multi-Unit Entry System

GF-2B Aiphone Back Box for GF Common 2-Wire Multi-Unit Entry System

2-module back box for GF Common 2-Wire Multi-Unit Entry System.




GF-2F 2 Module Front Frame Bracket for GF System

GF-2F 2 Module Front Frame Bracket for GF System

GF-2F Aiphone 2-Module Front Frame

2-module front frame for Aiphone GF system

Features

  • Full module panel construction
  • Vandal-proof zinc alloy diecast panels
  • Multiple bus lines from junction point to room station stations (max. 50) or entrance stations (max. 3)
  • One or two room stations
  • Optional doorbell button with different tone from entrance (one inside station only)
  • Call tone cutout with switch
  • Door release and light control from room station
  • System setup without using extra tools
  • Max 980' (300m) distance from junction to the farthest room station per bus line



GF-2P Aiphone Additional 2-Call Panel for GF Entry System

GF-2P Aiphone Additional 2-Call Panel for GF Entry System

GF-2P Aiphone Additional 2-Call Panel for GF Entry System

Additional 2-Call Panel for GF Entry System.




GF-3B Aiphone Back Box for GF

GF-3B Aiphone Back Box for GF

GF-3B Aiphone Back Box for GF Common 2-Wire Multi-Unit Entry System

  • Full module panel construction
  • Vandal-proof zinc alloy diecast panels
  • Multiple bus lines from junction point to room station stations (max. 50) or entrance stations (max. 3)
  • One or two room stations
  • Optional doorbell button with different tone from entrance (one inside station only)
  • Call tone cutout with switch
  • Door release and light control from room station
  • System setup without using extra tools
  • Max 980' (300m) distance from junction to the farthest room station per bus line



GF-3F Aiphone 3-Module Front Frame

GF-3F Aiphone 3-Module Front Frame

GF-3F Aiphone 3-Module Front Frame

3-module front frame.

Features
  • Full module panel construction
  • Vandal-proof zinc alloy diecast panels
  • Multiple bus lines from junction point to room station stations (max. 50) or entrance stations (max. 3)
  • One or two room stations
  • Optional doorbell button with different tone from entrance (one inside station only)
  • Call tone cutout with switch
  • Door release and light control from room station
  • System setup without using extra tools
  • Max 980' (300m) distance from junction to the farthest room station per bus line



GF-3P Aiphone Additional 3-Call Panel for GF Entry System

GF-3P Aiphone Additional 3-Call Panel for GF Entry System

GF-3P Aiphone Additional 3-Call Panel for GF Entry System

Additional 3-Call Panel for GF Entry System.

Features
  • Full module panel construction
  • Vandal-proof zinc alloy diecast panels
  • Multiple bus lines from junction point to room station stations (max. 50) or entrance stations (max. 3)
  • One or two room stations
  • Optional doorbell button with different tone from entrance (one inside station only)
  • Call tone cutout with switch
  • Door release and light control from room station
  • System setup without using extra tools
  • Max 980' (300m) distance from junction to the farthest room station per bus line



GF-4P Additional 4-Call Panel for GF Entry System

GF-4P Additional 4-Call Panel for GF Entry System

GF-4P Additional 4-Call Panel for GF Entry System

  • Full module panel construction
  • Vandal-proof zinc alloy diecast panels
  • Multiple bus lines from junction point to room station stations (max. 50) or entrance stations (max. 3)
  • One or two room stations
  • Optional doorbell button with different tone from entrance (one inside station only)
  • Call tone cutout with switch
  • Door release and light control from room station
  • System setup without using extra tools
  • Max 980' (300m) distance from junction to the farthest room station per bus line



GF-BC Aiphone Audio Bus Control Unit

GF-BC Aiphone Audio Bus Control Unit

GF-BC Aiphone Audio Bus Control Unit

Two wire, Audio Bus Control Unit.

Features
  • Full module panel construction
  • Vandal-proof zinc alloy diecast panels
  • Multiple bus lines from junction point to room station stations (max. 50) or entrance stations (max. 3)
  • One or two room stations
  • Optional doorbell button with different tone from entrance (one inside station only)
  • Call tone cutout with switch
  • Door release and light control from room station
  • System setup without using extra tools
  • Max 980' (300m) distance from junction to the farthest room station per bus line



GF-DA/B Aiphone Audio Module for GF: Multi-Unit Entry Systems

GF-DA/B Aiphone Audio Module for GF: Multi-Unit Entry Systems

GF-DA/B Aiphone Audio Module for GF: Multi-Unit Entry Systems

Adds audio to the GF: Multi-Unit Entry System.




GF-DP Aiphone Panel for GF-DA Speech Module

GF-DP Aiphone Panel for GF-DA Speech Module

GF-DP Aiphone Panel for GF-DA Speech Module

Panel for GF-DA Speech Module.

Features
    Full module panel construction
  • Vandal-proof zinc alloy diecast panels
  • Multiple bus lines from junction point to room station stations (max. 50) or entrance stations (max. 3)
  • One or two room stations
  • Optional doorbell button with different tone from entrance (one inside station only)
  • Call tone cutout with switch
  • Door release and light control from room station
  • System setup without using extra tools
  • Max 980' (300m) distance from junction to the farthest room station per bus line



GF-SW Aiphone Call Switch Module for GF Multi-Unit Entry System

GF-SW Aiphone Call Switch Module for GF Multi-Unit Entry System

GF-SW Aiphone Call Switch Module for GF Multi-Unit Entry System

Call Switch Module for GF Multi-Unit Entry System.

Features
  • Full module panel construction
  • Vandal-proof zinc alloy diecast panels
  • Multiple bus lines from junction point to room station stations (max. 50) or entrance stations (max. 3)
  • One or two room stations
  • Optional doorbell button with different tone from entrance (one inside station only)
  • Call tone cutout with switch
  • Door release and light control from room station
  • System setup without using extra tools
  • Max 980' (300m) distance from junction to the farthest room station per bus line



GF-VA Aiphone Video Module for GF Multi-Unit Entry System

GF-VA Aiphone Video Module for GF Multi-Unit Entry System

GF-VA Aiphone Video Module for GF Multi-Unit Entry System

Adds video to the GF: Multi-Unit Entry Systems.




GF-VBC/A Aiphone Video Bus Control Unit for GF: Multi-Unit Entry System

GF-VBC/A Aiphone Video Bus Control Unit for GF: Multi-Unit Entry System

GF-VBC/A Aiphone Video Bus Control Unit for GF: Multi-Unit Entry System

Video Bus Control Unit for systems with a concierge station.(1 per system)




GF-VP Aiphone Video Module Panel for GF: Multi-Unit Entry Systems

GF-VP Aiphone Video Module Panel for GF: Multi-Unit Entry Systems

GF-VP Aiphone Video Module Panel for GF: Multi-Unit Entry Systems

Allows for easy installation of the Video Module (GF-VA).






Additional System Equipment
GF-1DK Audio Only Tennant Handset Station

GF-1DK Audio Only Tennant Handset Station

Aiphone GF-1DK Audio Only Tennant Intercom Station

Audio handset with door release for systems with concierge station
(1 or 2 per apartment, max 150 handsets per system)




GF-4Z Aiphone 4-Monitor Video Distribution Adaptor

GF-4Z Aiphone 4-Monitor Video Distribution Adaptor

GF-4Z Aiphone 4-Monitor Video Distribution Adaptor

4-Monitor Video Distribution Adaptor for GF: Multi-Unit Entry System. One per every four moniters.




W-DIN11 Aiphone DIN-Rail for GF-BC

W-DIN11 Aiphone DIN-Rail for GF-BC

W-DIN11 Aiphone DIN-Rail for GF-BC

DIN-Rail for GF-BC, GF-VBC, GFW-VBC, and GF-4Z.

Features
  • Full module panel construction
  • Vandal-proof zinc alloy diecast panels
  • Multiple bus lines from junction point to room station stations (max. 50) or entrance stations (max. 3)
  • One or two room stations
  • Optional doorbell button with different tone from entrance (one inside station only)
  • Call tone cutout with switch
  • Door release and light control from room station
  • System setup without using extra tools
  • Max 980' (300m) distance from junction to the farthest room station per bus line





Power Supply
PS-2410LC Aiphone 24V DC, 1A Power Supply

PS-2410LC Aiphone 24V DC, 1A Power Supply

PS-2410LC Aiphone 24V DC, 1A Power Supply

24V DC, 1 A power supply.

Features
  • 120V AC
  • 50/60Hz
  • 35W
Used for Aiphone intercoms
  • GF-BC(GF)
  • GF-VBC
  • GFW-VBC(GF)
  • MAW-B





Aiphone Wire & Cable