| Fire Alarm Systems > FireLite Alarms > Fire Alarm Control Panels | ![]() |
||
![]()
| |||
FireLite MS-2 Conventional Two Zone, 24 VDC Conventional Control Panel (MS2)
MS-2 Two-Zone Fire Alarm Control PanelFire•Lite's MS-2 and MS-4 Fire Alarm Control Panels bring the latest in microprocessor technology to conventional fire controls. The MS-2 is compatible with the new I3 smoke detectors from System Sensor, and provide such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using manufacturer protocol for System Sensor, Wheelock and Gentex appliances.. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires. |
FireLite MS-4 Conventional Four Zone Fire Alarm Control Panel
FireLite MS-4 Four Zone Fire Alarm Control PanelThe FireLite MS-4 Fire Alarm Control Panel brings the latest in microprocessor technology to conventional fire controls. The MS-4 is compatible with the new I3 smoke detectors from System Sensor, and provide such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using three selections for manufacturer protocol. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires. |
| Conventional Control Panels with Built-In Communicator |
FireLite MS-10UD-7 Ten Zone Fire Alarm Control Panel
FireLite MS-10UD-7 Ten Zone Fire Alarm Control PanelThe MS-5UD-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-10UD-7(E) is a ten-zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/download. |
FireLite MS-5UD-3 Five Zone Fire Alarm Control Panel
FireLite MS-5UD-3 Five Zone Fire Alarm Control PanelThe MS-5UD-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-10UD-7(E) is a ten-zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/download. |
FireLite MS-9050UD 50-Point Intelligent Fire Alarm Control Panel (MS9050UD)
FireLite MS-9050UD 50-Point Intelligent Fire Alarm Control PanelSophisticated Performance at the Cost of Conventional System. The MS-9050UD Fire Alarm Control Panel offers state-of-the-art technology with easy installation, operation, and maintenance. Suited for stand-alone applications, the MS-9050UD is ideal for smaller facilities such as apartment complexes, banks, cinemas, child care and elementary schools, department stores, food stores, places of worship, restaurants and small retail outlet stores. |
FireLite MS-9200UDLS 198-Point Addressable Control (MS9200UDLS)
FireLite MS-99200UDLS 198-Point Intelligent Fire Alarm Control PanelFire-Lite's MS-9200UDLS Intelligent Addressable Fire Alarm System with new LiteSpeedTM SLC protocol is ideal for small to medium facilities. |
FireLite MS-9600 Rev. 2/DACT-UD Addressable FACP with Optional 2nd Loop (MS9600)
MS-9600 Rev. 2/DACT-UD Intelligent Addressable FACP with Optional 2nd LoopThe Fire•Lite MS-9600 is a compact, cost-effective, intelligent addressable fire alarm control panel with a capacity of 318 addressable Fire•Lite devices on one Signaling Line Circuit (SLC) or a total of 636 addressable points with an optional second loop (SLC-2). An optional 14.4K Baud modem (DACT-UD) is available for remote site upload/download and/or remote monitoring. |
FireLite ACC-25/50 Emergency Voice Evacuation Control
ACC-25/50 Emergency Voice Evacuation ControlThe Fire•Lite ACC-25/50 is a state-of-the-art, single or dual amplifier (25 watts each) Emergency Voice Evacuation Control (EVAC) panel. The panel provides the ability to record five field programmable messages (up to 60-seconds or total message duration) with an integral microphone of from an external audio source. Significant technological enhancements set the ACC-25/50 apart from other EVAC panels. These enhancements include full supervision in both active (alarm or music) and standby conditions, supervision of amplifier outputs, field wiring, message generators, all tone generators and the microphone. The integral power supply is capable of charging up to 18 Amp hour batteries, which can be housed in the ACC-25/50 cabinet. |
FireLite ACC-25/50ZS Voice Evacuation Control Panel
ACC-25/50ZS - Audio Command Center
|
FireLite FC-25/50DA Distributed Audio Emergency Voice Evacuation System
FC 25/50 Distributed Audio Emergency Voice Evacuation ControlThe Fire•Lite FIRE•COMMAND•25/50DA is a state-of-the-art, compact, Distributed Audio (DA) panel. The FIRE•COMMAND•25/50DA is offered in a self-contained, cost-effective design and includes a 25 Watt, 25 VRMS audio amplifier and integral tone generator. Additionally, an optional digital message generator module provides a factory-prerecorded voice announcement and field record and playback capability. |
| Fire Suppression Control Panels |
FireLite MRP-2001 Deluge/Preaction Control Panel
FireLite MRP-2001 Deluge/Preaction Control PanelThe MRP-2001 is a six-zone FACP for single and dual hazard deluge and preaction applications. The MRP-2001 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing. The MRP-2001 is compatible with System Sensor's i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory 'freeze' signal when the ambient temperature falls below the detector rating of approximately 45ºF (7.22ºC). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Fire·Lite Device Compatibility Document for a complete listing of compatible devices. |
FireLite 411 Slave Digital Alarm Communicator Transmitter (DACT)
411 and 411UD Digital Alarm Communicator Transmitters (DACT)The Fire-Watch 411 Series from Fire•Lite are compact, multifaceted, slave Digital Alarm Communicator Transmitters (DACTs) designed for a variety of fire, and non-fire applications. The series consists of two models: the 411 and 411UD, providing three and four monitoring channels (inputs) respectively. These slave DACTs are a cost-effective solution for applications that require an existing (or new) Fire Alarm Control Panel to transmit system status to an off-site monitoring facility for Central or Remote Station compliance. |
FireLite 411UD Slave Digital Alarm Communicator Transmitter (DACT)
411 and 411UD Digital Alarm Communicator Transmitters (DACT)The Fire-Watch 411 Series from Fire•Lite are compact, multifaceted, slave Digital Alarm Communicator Transmitters (DACTs) designed for a variety of fire, and non-fire applications. The series consists of two models: the 411 and 411UD, providing three and four monitoring channels (inputs) respectively. These slave DACTs are a cost-effective solution for applications that require an existing (or new) Fire Alarm Control Panel to transmit system status to an off-site monitoring facility for Central or Remote Station compliance. |
FireLite 411UDAC Digital Alarm Communicator Transmitter (DACT)
411UDAC Digital Alarm Communicator Transmitters (DACT)The Fire-Watch 411UDAC from Fire•Lite is a compact, multifaceted, stand-alone or slave Fire Alarm Communicator designed for a variety of fire and non-fire applications. It provides four channels (inputs) that accept waterflow devices, two- and four-wire smoke detectors, pull stations, and other normally-open contact devices. The 41UDAC is a cost-effective solution for applications that require an existing (or new) fire alarm control or non-fire control panel to transmit system status to an off-site monitoring facility for Central or Remote Station compliance. |
FireLite UDACT-F Digital Alarm Communicator Transmitter (DACT)
UDACT-F Digital Alarm Communicator Transmitters (DACT)The UDACT-F is compact in size and may be mounted inside the host control panel or may mount externally in a separate cabinet. EIA-485 annunciator communications bus and regulated 24-volt connections are required. The UDACT-F transmits 198 points or 56 zones when connected to the MS-9200, up to 636 points or 98 zones when connected to the MS-9600, and 56 zones when connected to the Sensiscan 2000. |
FireLite CHG-120F Remote Battery Charger (120 AH)
CHG-120F Remote Battery Charger (120 AH)The Fire•Lite CHG-120F is a state-of-the-art battery charging system designed for use with the Fire•Lite MS-9600, MS-9200 (requires MS-9200 circuit board #71741) and the Sensiscan 2000. It is designed to charge lead-acid batteries between 25 and 120 ampere-hours (AH). |
FireLite CHG-75 State-of-the-Art Charging System (25&75 AH)
CHG-75 State-of-the-Art Charging System (25&75 AH)The Fire•Lite CHG-75 is a state-of-the-art battery charging system designed for use with the Fire•Lite MS-9600, MS-9200 and the Sensiscan 2000. * Has built-in monitor module for direct connection to the MS-9200UD or MS-9600 SLC loop. It is designed to charge lead-acid batteries between 25 and 75 ampere-hours (AH). |
FireLite FCPS-24FS6 (6 amps/4 NACs/Built In Sync)
FireLite FCPS-24FS6 NAC Power SupplyThe FCPS-24FS6 is a compact, cost-effective, 6-amp remote power supply with battery charger. The FCPS-24FS6 may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may be stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits configured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS-24FS6 also contains a battery charger capable of charging up to 18 Amp Hour batteries. |
FireLite FCPS-24FS8 (8 amps/4 NACs/Built In Sync)
FireLite FCPS-24FS8 NAC Power SupplyThe FCPS-24FS8 is a compact, cost-effective, 8-amp remote power supply with battery charger. The FCPS-24FS8 may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may be stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The FCPS-24FS8 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits configured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS-24FS6 also contains a battery charger capable of charging up to 18 Amp Hour batteries. |
FireLite XRM24 Expander Transformer: 3.6 Amps, 24 Volts
FireLite BB17F Battery Cabinet: Required for 17 Amp Hour and Larger Batteries
FireLite BB-26 Battery Back Box
FireLite BB-26 Battery Back Box |
FireLite BB-55F Battery Back Box
FireLite BB-55F Battery Back Box |
FireLite BB-6F Optional Cabinet for up to Six Modules Mounted on CHS-6 Chassis
FireLite BB-6F Optional cabinet for up to six modules mounted on CHS-6 chassis |
FireLite CHS-6 Chassis, Mounts up to Six Multi-modules in a BB-6F Cabinet
FireLite CHS-6: Chassis, Mounts up to Six Multi-modules in a BB-6F Cabinet |
FireLite DP-51050 Optional Dress Panel
FireLite DP-51050 Optional Dress Panel |
FireLite PRN-6F UL Listed Compatible Event Printer
FireLite PRN-6F UL Listed Compatible Event PrinterUses tractor-fed paper. |
FireLite PRT/PK-CABLE Printer/Personal Computer Interface Cable
FireLite PRT/PK-CABLE Printer/Personal Computer Interface Cable |
FireLite SLC2 159 Det & 159 Control, Relay & Module
FireLite SLC2 159 Det & 159 Control, Relay & Module
FireLite TR-CE Trim Ring for Semi-Flush Mount, Red
FireLite TR-CE Trim Ring for Semi-Flush Mount, Red |