| Approvals: |
UL-2075 Listed |
| Extremely Low Current Draw: |
Standby 20 ľAmp, Alarm 60 mAmp, Trouble 30 mAmp |
| No False Alarms: |
Genetic engineering creates the world's first biotechnology-based infrared gas sensor. |
| Powered by 12v DC: |
Can be directly wired into standard security/burglar panel Designed for 4-6 wire connection to 12v DC alarm system control panels. |
| Sound Output: |
85 dB at 10 feet |
| Non-latching Alarm: |
Automatic reset with dual relays |
| Detection Technology: |
Solid-state Infra-Red (SIR) sensor with
reservoir system. |
| Operating Environment: |
40°F to 100°F; 15% to 95% RH |
| Relay Output: |
1 set of form 'C' dry contacts
(non-latching), current rating 1 amp @ 12 volts |
| Alarm Response Times: |
Below 35 ppm no alarm 70 ppm alarm within 60 to 240 minutes 150 ppm alarm within 10 to 50 minutes 400 ppm alarm within 4 to 15 minutes |
| Signals: |
Normal Operation: Red LED flashes every 30 seconds indicating that the alarm is powered & active.
Alarm Condition: Flashing red light and pulsating horn. Red LED is continuous with an 85 db alarm pulsing 2 seconds on; 4 seconds off. After 4 minutes, the alarm will once again sound until the unsafe CO Concentration is reduced.
Trouble/Service: Detector self tests every 10 minutes. Detector will beep and indicator/test button will flash twice every 30 seconds if a fault is detected.
Test: One chirp, then red light flashes 4 to 5 times followed by 2 alarm signals. |
| Unit Dimensions: |
5" diameter, 1.75" depth |
| Warranty: |
6 year Limited Manufacturers Warranty (Detector and Sensor) |