Honeywell's VISTA-10P is a six-zone security alarm control panel designed to address security dealers' most important needs. It significantly reduces end-user training and central station costs thanks to user-friendly features that make operation easier than ever, and offers increased upsell opportunities through its expansion capabilities and flexibility. The feature-rich panel is the industry's most economical control and is ideally suited for a wide range of applications.
Features
- Six hardwired zones on board
- 16 wireless expansion zones totaling 22 protection zones
- Eight independent keyfob zones allow two wireless keys to be programmed without using any of the 22 zones
- 32 Event log
- 16 user codes
- One configurable zone type allows installers to create their own custom zone type
- Two on-board triggers
- Four output devices using a 4204 relay module
- Flexible function keys allow single button arming
- One programmable macro key
- Viewable on system keypad display
- Exit countdown
- Time and date*
- Event log
- Two schedules:
- Can activate relays on programmed times or on events
- Latchkey reports to a pager
- "User Access" time windows
- Chime by zone
- 4286 Phone Module allows system control from any touchtone phone
- Four output devices with multiple actions per device
- Turn lights on when system disarms with a 4204 relay
- Flash same lights when system is in alarm with a 4204 relay
- UL approved for ANSI/SIA CP-01-2000
* Requires 6160 Custom Alpha keypad
Security Dealer Features
- Contains features to reduce false alarms
- Dynamic Signaling
- Reduces redundant reporting to the central station when multiple reporting methods are used (digital dialer, AlarmNet radio)
Electrical Specifications:
- Aux. power 12VDC, 600mA max
- Seven hour standby at 400mA aux load with four amp hour battery
- 16.5VAC/25VA transformer
- Alarm output 12VDC, 2.0 amps max
- For UL installations, combined aux and alarm output cannot exceed 700mA
Output Control:
- Supports multiple output devices, one 4204 and two triggers
Zones:
- Six hardwired zones
- Selectable response: 10msec, 350msec, 750msec
- 16 selectable zone types plus one configurable zone type
- Programmable swinger suppression
Expansion Devices:
- 4204 Up to four relays 15mA standby (each active relay draws an additional 40mA)
Accessories
- 4286 VIP Voice Module 220mA
- 5881ENL RF Receiver supports up to eight zones 60mA,
- 5881ENM supports up to 16 zones 50mA
- 5883 Transceiver supports up to 16 zones 80mA
- Supports Eagle 1225 and 1221 boards
Keypads:
- 6160 Custom Alpha (required for programming) 100mA
- 6160V Custom Alpha Voice 100mA
- 6150 Fixed English LCD - 85mA/40mA
- 6150V Fixed English Voice LCD 85mA/40mA
- 6150RF Fixed English RF LCD - 85mA/40mA
- 6148 Fixed English LCD 70mA/30mA
Agency Listings:
- UL Residential Fire, Burglary and CSFM
Smoke Detectors:
- Supports four-wire smoke detectors
Communications:
- Touchtone or pulse
- Formats supported:
- ADEMCO Contact ID
- ADEMCO 4 + 2 Express
- ADEMCO low speed
- Sescoa/Radionics
- 3 + 1, 4 + 1 and 4 + 2 reporting
- Reporting capabilities:
- Split
- Dual
- Split/Dual True dial tone detection
- Low battery reports 11.2 11.6VDC
- AC loss and restoral reporting supported